SOLID O2 • MEDHBOT STANDARDS

MedHBOT Standards & Compliance

A practical operating framework for safer Medium Hyperbaric Oxygen Therapy environments—covering equipment, installation, people, procedures, servicing and ongoing support.

Version 2.1Revision date 22 August 2026South African operating context
PURPOSE

A chamber is only one component

A professional MedHBOT environment is the complete operating system around Medium Hyperbaric Oxygen Therapy. It includes suitable equipment, correct installation, trained operators, documented procedures, scheduled servicing, maintenance, local repair capability and ongoing technical support.

These standards help owners, operators and clients ask better questions and distinguish a supported professional environment from an unsupported equipment purchase.

Status of this document: This is a Solid O2/HM operational framework. It is not legislation, a statutory certification scheme, medical advice or a substitute for manufacturer instructions, applicable law, competent risk assessment or professional clinical judgement.
PRESSURE • BREATHING GAS • AIR MOVEMENT

How the three environments differ

The chamber pressure, the atmosphere surrounding the occupant and the gas delivered to the airway are separate technical questions. A pressure number alone does not define the treatment environment.

Clinical HBOT

Typical pressure: commonly 2.0–3.0 ATA for many clinical protocols; authoritative definitions may include exposures above 1.4 ATA.

Chamber atmosphere: a monoplace chamber may be filled with near-100% medical oxygen. A multiplace chamber is commonly pressurised with air while oxygen is delivered by mask or hood.

Airflow and exhaust: engineered gas supply, ventilation, exhaust and carbon-dioxide control are integral to the installation.

Control: formal medical oversight, trained staff and rigorous fire-safety procedures.

MedHBOT

Typical pressure: 1.3–2.0 ATA.

Chamber atmosphere: ordinarily pressurised with ambient air. Supplemental oxygen from suitable concentrator equipment is delivered to the client by mask or nasal interface.

Oxygen performance: commonly about 93–97% at the equipment outlet, subject to model specifications, flow rate, testing and servicing.

Airflow and exhaust: in common fabric systems the compressor continues supplying air after working pressure is reached, while relief/exhaust valves discharge an approximately corresponding flow.

Lower-pressure / mHBOT

Typical pressure: commonly around 1.2–1.3 ATA.

Chamber atmosphere: ordinarily ambient air, with concentrator oxygen supplied by mask or nasal interface where fitted.

Airflow and exhaust: many fabric systems also use continuous compressor airflow and relief-valve discharge.

Variation: equipment quality, oxygen output, maintenance, operator training and oversight vary. A low-pressure chamber is not automatically a compliant MedHBOT environment.

THREE PILLARS

Compliance is demonstrated across the whole environment

1. Equipment & installation

Equipment must be appropriate for the intended pressure, use and operating environment. Components need compatible specifications, traceable records, pre-use checks and maintenance pathways.

2. People & procedures

Operators require equipment-specific training, clear responsibilities, screening and escalation processes, communication competence and emergency preparedness.

5

3. Service & support

Professional operation depends on documented service intervals, inspections, oxygen-performance checks, accessible repairs, parts, warranty administration and continuing technical support.

CORE EXPECTATIONS

What a professional MedHBOT solution should address

~

Equipment identity

Document the chamber, compressor, oxygen concentrator, breathing interface, hoses, valves, monitoring and safety equipment. Confirm model, serial number, intended pressure and manufacturer requirements.

r

Installation & environment

Assess room ventilation, heat, electrical supply, trip hazards, access, clearances, emergency egress, fire risk and safe discharge points before commissioning.

Operator competence

Train operators on the exact system they will use, including checks, compression and decompression, client communication, cleaning, abnormal-event response and escalation.

i

Documented operation

Use controlled procedures for client screening, consent where applicable, pre-use inspection, session records, hygiene, incident reporting, emergency response and post-session checks.

5

Maintenance & servicing

Follow equipment-specific schedules. Record inspections, filter and component changes, oxygen testing, valve checks, repairs and service outcomes. Remove unsafe equipment from use.

Warranty & ongoing support

Confirm warranty terms, response routes, spare-parts availability, local repair capability, technical advice and continuing operator support before purchase.

ASSESSMENT STATUS

Evidence should support every status

A badge or label is not enough. The current state should be supported by dated, site-specific records and reviewed whenever equipment, staff, procedures or service status changes.

Assessment area Examples of evidence Suggested status
Equipment & installation Model and serial records, specifications, commissioning record, site risk assessment and pre-use checks Compliant / Action required / Not assessed
Operator training Named operators, training records, competency review, emergency drills and scope boundaries Current / Renewal due / Incomplete
Procedures & records Screening, session, cleaning, incident, escalation and emergency documentation Implemented / Partial / Missing
Servicing & maintenance Service dates, oxygen-performance results, inspection history, repairs and component changes Current / Due soon / Overdue
Support & warranty Support contact, warranty status, parts availability, repair pathway and technical escalation Confirmed / Limited / Unconfirmed
LIMITS AND RESPONSIBILITIES

What this framework does—and does not—establish

Solid O2/HM review can describe alignment with this operational framework at a point in time. It does not create regulatory approval, guarantee clinical outcomes or replace an owner’s continuing legal and safety duties.

Compliance status can change. Overdue servicing, untrained staff, equipment alteration, relocation, missing records or operation outside manufacturer instructions can invalidate a previous assessment.

Where a manufacturer instruction, applicable law, fire-safety requirement or competent professional assessment is more specific or more stringent, that requirement takes precedence.

PRACTICAL PATH

Prepare for a standards review

Start with accurate site and equipment records, confirm the operating team, gather procedures and training evidence, and check the current service position. Solid O2 can then identify gaps and agree practical next actions.

Review sequence

  1. Record the site and equipment
  2. Confirm staff and training
  3. Review procedures and risks
  4. Check service and maintenance
  5. Resolve actions and document status
REFERENCES

Authoritative sources

These sources support the technical distinctions and safety principles used on this page. Equipment-specific instructions, applicable South African law and competent professional advice take precedence.

1. Undersea and Hyperbaric Medical Society — Definition and credentialing guidance

Scientific definition of hyperbaric oxygen therapy and clinical credentialing guidance.

Open source ↗

2. Undersea and Hyperbaric Medical Society — Safety documents

Technical and fire-safety guidance, including the distinction between oxygen-filled monoplace and air-filled multiplace environments.

Open source ↗

3. Undersea and Hyperbaric Medical Society — Treatment protocol FAQ

General pressure ranges commonly used in clinical hyperbaric treatment protocols.

Open source ↗

4. ISO 80601-2-69:2026

International safety and essential-performance requirements for oxygen concentrator equipment.

Open source ↗

5. ASME PVHO-1 — Pressure Vessels for Human Occupancy

Engineering and construction framework for pressure vessels intended for human occupancy.

Open source ↗

6. U.S. FDA — Safe use of hyperbaric oxygen therapy devices

Manufacturer instructions, fire prevention, trained operation, inspection and maintenance.

Open source ↗

7. NFPA 99 (2024 edition)

Health-care facilities code covering hyperbaric facility fire and life-safety considerations.

Open source ↗

NEXT STEP

Build a supported MedHBOT environment

Speak to Solid O2 about equipment selection, installation, operator training, servicing, maintenance, local repairs and continuing technical support.